Yes, new ASA/PVC sheets can go over an old metal roof when the old sheets are only surface-rusted, the frame is sound, and the frame can carry both layers: about 3.5 kg per m² for a 0.45 mm steel sheet plus about 5.2 kg per m² for a 2.5 mm Santiago sheet, roughly 8.7 kg per m². The new sheets must be screwed through the old roof into purlins less than 700 mm apart. Strip the old roof instead when it is rusted through, leaking into wet insulation, or over an animal house or near the sea.

Santiago Import Export Co., Ltd (Vietnam) makes ASA/PVC roof tile sheets and corrugated roofing sheets and exports them by the container. WhatsApp +84 935 391 495 (Mr. Quyen), hotline +84 965 437 316 (Mrs. Ly).

The questions below come in the order an owner has to answer them: whether to overlay or strip, the extra weight, purlin spacing, the screws, what happens to the old sheet underneath, building rules, and which sheet to lay on top.

Safety helmet on new blue corrugated sheets laid over a factory roof, with red sheets at the far end, Vietnam

Safety helmet on new blue corrugated sheets laid over a factory roof, with red sheets at the far end, Vietnam

 

Should you overlay an old metal roof or strip it off?

 

Overlaying saves the strip-off, keeps the building dry during the work and leaves no old sheet to dispose of. Stripping costs more labour but shows every purlin and rafter, so hidden rot and rust get fixed before the new roof goes on. The condition of the old roof decides.

Old roof conditionOverlayStrip off
Surface rust, no holes, frame soundPossiblePossible
Rusted through, holes, crumbling lapsNoYes
Wet or mouldy insulation under the sheetsNoYes
Sagging or rotten frameNoYes, repair the frame
Animal house, fertiliser store or within a few km of the seaNot advised: rust keeps working underneathYes
Two roofs already on top of each otherNoYes

Old metal roof sheets rusted through along the laps, being stripped beside newer sheets, Vietnam

Old metal roof sheets rusted through along the laps, being stripped beside newer sheets, Vietnam

How to check the frame once the old sheets are off is set out in our guide to checking an old roof frame before re-roofing.

 

How much weight does a PVC roof over metal add?

 

An overlay adds the full weight of the new roof, because the old one stays. Steel weighs about 7.85 kg per m² for each millimetre of thickness, so a 0.45 mm steel sheet weighs about 3.5 kg per m² before laps. A 2.5 mm Santiago ASA/PVC sheet weighs about 5.2 kg per m².

LayerWeight per m² (approx.)
Old 0.45 mm steel sheet3.5 kg
New 2.5 mm ASA/PVC sheet5.2 kg
Both layers8.7 kg
New 2.5 mm ASA/PVC sheet after stripping5.2 kg

Add the weight of any battens or spacers between the layers. Ask a structural engineer to confirm the rafters and purlins when the frame is old, light or already sagging. Our article on lightweight roofing materials for old buildings compares other coverings.

 

Do you need new purlins for an overlay?

 

Usually yes. ASA/PVC sheets need support less than 700 mm apart along the slope, and metal roofs are often laid on wider purlin spacing. Fix new battens or top-hat purlins over the old sheets, through them into the old purlins or rafters, at under 700 mm, then lay the new sheets on the battens.

  • Measure the existing purlin spacing from inside before ordering
  • Run the new battens across the slope, fixed through the old sheet into the frame
  • Keep the battens in one straight plane with a string line, so the new roof does not follow dents in the old one
  • A foil layer or insulation board can lie between the battens, on the old sheet

Installers laying foil insulation and red tile sheets over an existing roof on a house in Vietnam

Installers laying foil insulation and red tile sheets over an existing roof on a house in Vietnam

 

Which screws fix new sheets through an old metal roof?

 

The screws must pass through the new sheet, the gap and any batten, and still bite the purlin or batten below. Santiago's standard fixing is a 70 mm screw with washer and ASA cap through a pre-drilled 6 mm hole at the top of the wave; fixed onto new battens, that standard set works.

  • Fixing straight through both sheets into an old purlin needs a longer screw; send the build-up (sheet, gap, batten) and Santiago supplies screws of the right length
  • Always fix through the top of the wave of the new sheet, never the valley
  • Use 4 – 5 screw sets per m²
  • Do not let a new screw sit in an old, rusty hole in the metal below

 

What happens to the old metal sheet under the new roof?

 

It stays where it is, and whatever was wrong with it keeps going. Rust spreads under the new roof where nobody can see it, and warm, moist air from inside can condense on the cold underside of the new sheet and drip onto the old one. That is why overlay suits dry stores and offices with sound sheets, and suits poorly animal houses, wet process buildings and coastal sites.

  • Clean loose rust and dirt off the old sheet before covering it
  • Leave the eave and ridge of the gap open to the air, or vented, so moisture can escape
  • Do not trap wet insulation; replace it or strip the roof
  • Check gutters: the new roof sits higher and its eave may overshoot an old gutter

More on stopping drips under sheet roofs is in our guide to roofing sheet condensation and anti-drip.

 

Do building rules allow a roof over a roof?

Rules differ by country, so check locally. In the United States, the International Residential Code (section R908, re-roofing) does not allow a new covering over an existing roof that is water-soaked or too deteriorated to be a sound base, or over two or more existing layers. Asbestos cement roofs have their own rules almost everywhere; see replacing asbestos roof sheets with PVC.

 

Which ASA/PVC sheet goes over an old metal roof?

 

Factories, stores and farm buildings normally take a corrugated ASA/PVC sheet; houses that want a tiled look take the roof tile sheet. Both are laid the same way over new battens.

  • Roof tile sheet: 1.05 m wide, 0.96 m cover width, cut to length in 219 mm tile steps
  • Corrugated sheet: 5-wave, 6-wave and 11-wave profiles
  • Weight: about 5.2 kg per m² at 2.5 mm
  • Rain noise about 80% lower and 6 – 8 °C cooler under the roof than bare metal sheet, in Santiago's tests
  • Warranty: 10 years for 2.5 mm and thicker sheet installed as Santiago recommends

New red ASA/PVC tile sheet roof laid next to a grey corrugated metal roof, Vietnam

New red ASA/PVC tile sheet roof laid next to a grey corrugated metal roof, Vietnam

For a house that should look tiled after the overlay, see the ASA/PVC roof tile sheet, 1.05 m wide. If the old sheets have to come off after all, follow our guide to replacing a rusted metal roof with PVC sheets.

What does re-roofing an old metal warehouse look like?

The short starts with a flame put to a stack of grey and red tile sheets, then Mr Quyen crouches on grey tile sheets in the Santiago factory. It ends on a blue warehouse roof where installers lay new sheets on the frame, with Mr Quyen standing on the roof in a white helmet.

Re-roofing a warehouse with Santiago ASA/PVC sheets (Santiago video on YouTube).

More short videos on light roofs

Both clips below come from Santiago's own YouTube channel and were filmed at the factory in Vietnam or on Santiago roofs.

Light but tough: the truck test

The 26-second short shows a Santiago truck rolling across two blue sheets on the yard, one tile-profile and one corrugated. Treat it as a demonstration: on a roof, purlins still go less than 700 mm apart.

Truck test on Santiago ASA/PVC sheets (Santiago video on YouTube).

What does fitting a new grey tile roof look like?

Installers screw grey Santiago tile sheets down on a roof while Mr Quyen and a colleague walk along the finished section near the gutter. The short opens in the factory with a green sheet.

Santiago uPVC tile roofs on site (Santiago video on YouTube).

Santiago – a leading exporter of ASA/PVC roofing from Vietnam

Santiago roofing is produced and loaded into containers at our factory in Vietnam. It has been exported to India since 2023, Thailand since 2024 and the USA since 2025. Every export shipment comes with a commercial invoice, packing list, bill of lading and a certificate of origin (C/O) issued by Vietnam's Ministry of Industry and Trade, which importers use to claim the duty preference of their trade agreement.

ItemDetails
HS code3925.90.00 (ASA/PVC roofing sheets)
Certificate of originForm D (ASEAN), Form AI (India), Form AK / VK (Korea), Form AJ / VJ (Japan), Form VC (Chile), CPTPP proof of origin
Shipped fromVietnam, by container

Certificate of origin Form AI (ASEAN–India) for Santiago ASA/PVC roofing sheets, HS 39259000, certified on 24 September 2026. Buyer details are hidden.

Certificate of origin Form AI (ASEAN–India) for Santiago ASA/PVC roofing sheets, HS 39259000, certified on 24 September 2026. Buyer details are hidden.

The Santiago team beside a loaded export container at the factory, November 2024

The Santiago team beside a loaded export container at the factory, November 2024

Loading Santiago roof tiles into an export container

Loading Santiago roof tiles into an export container

 

Frequently asked questions

 

Can PVC roofing sheets go over an existing metal roof?

Yes, when the old sheets have only surface rust, the frame is sound and can carry both layers, and the new sheets are fixed to supports less than 700 mm apart.

 

How much weight does an overlay add?

About 5.2 kg per m² for a 2.5 mm Santiago ASA/PVC sheet on top of the old roof; with a 0.45 mm steel sheet underneath, both layers weigh about 8.7 kg per m².

 

Do I need longer screws for a roof over a roof?

Only when fixing straight through both sheets into the old purlins. Fixed onto new battens over the old roof, the standard 70 mm screw with ASA cap works.

 

When should I strip the old metal roof instead?

When it is rusted through, the insulation under it is wet, the frame sags, there are already two layers, or the building is an animal house or near the sea.

 

Will a PVC overlay stop rain noise from the old metal roof?

Rain hits the new ASA/PVC sheet, not the metal. In Santiago's tests, rain noise under ASA/PVC is about 80% lower than under bare metal sheet.

 

Read more

 

 

Sources for the figures in this article

  • Profiles, 2.5–3.0 mm thickness and 10-year warranty: Santiago ASA/PVC product specification.
  • About 6–8 °C cooler than bare metal sheet and about 80% less rain noise: Santiago's own comparisons on finished roofs in Vietnam.
  • HS code 3925.90.00: Harmonized System Chapter 39 (builders' ware of plastics), as applied in Vietnam's export tariff.
  • Certificates of origin (Form D, AI, AK/VK, AJ/VJ, VC, CPTPP): issued by Vietnam's Ministry of Industry and Trade under the country's free trade agreements.
  • Minimum order of one 40 ft container (about 5,000 m) and about 5 days for production and loading: Santiago export desk, October 2026.

Updated 03/11/2026. Santiago Import Export Co., Ltd, Vietnam. WhatsApp +84 935 391 495 (Mr. Quyen), hotline +84 965 437 316 (Mrs. Ly), email salessantiagoroofing@gmail.com.