Mr Quyen - Santiago. Posted 14/11/2026
Condensation forms when warm, humid air meets a surface colder than itself, and the water vapour turns to droplets. Bare metal sheets lose heat quickly to a clear night sky, so their undersides often drip by morning. A plastic sheet conducts heat less than metal, which helps, but no sheet stops condensation on its own: ventilation, less moisture inside and careful detailing still matter.

White corrugated sheets installed on a roof, Vietnam
Why do corrugated roofing sheets drip on the inside?
Air always holds some water vapour, and warm air holds more than cold air. When that air touches a surface cold enough, it cannot keep all the vapour, and the extra water settles on the surface as droplets. On a corrugated roof the droplets run down to the lowest point of each wave and fall.
The surface gets cold in a way many owners do not expect. On a clear, calm night a roof sheet radiates heat to the open sky and can end up colder than the air around it. Thin bare metal does this quickly. By early morning the underside is wet, and the drips look like a leak even though no rain has fallen.
It is worst where the air inside is moist: animal houses, laundries, kitchens, wet processing halls, unheated stores in damp climates, and buildings near water. A UK barn on an autumn morning and a coastal store in the tropics after a cool night show the same thing.
Is it condensation or a leak?
| Clue | More likely condensation | More likely a leak |
|---|---|---|
| When it drips | After cold, clear nights, also on dry days | Only during or after rain |
| Where | Over a wide area, drops along many waves | At one spot: a screw, an overlap, the ridge or a flashing |
| Weather | Calm, clear, cool nights | Wind-driven rain |
| What you see | Fine droplets across the underside | A water trail from a fixing or lap |
If it is a leak, the usual causes are screws placed in the valley instead of on the top of the wave, a side lap of less than one wave, a slope below 20%, or gaps at the ridge and flashings. Santiago's sheets are fixed with 70 mm screws through the top of the wave over a purlin, with ASA caps, into pre-drilled 6 mm holes.

Blue corrugated sheets laid on the ground, Vietnam
What does "anti condensation" mean for corrugated roofing sheets?
In UK listings the phrase usually describes a metal sheet supplied with an absorbent fleece or felt layer bonded to the underside. The layer holds the droplets until they evaporate instead of letting them fall. It treats the symptom; the moist air and the cold surface are still there.
Santiago's ASA/PVC sheets are not sold with a fleece layer. Their underside is the milky-white PVC base, one of four co-extruded layers. Their advantage is the material itself, covered below.
Do plastic roofing sheets get condensation?
They can, but less readily than bare metal. Plastic conducts heat far less than metal, so the underside of the sheet does not cool as sharply on a clear night. In a very humid building, though, any surface that drops below the dew point of the air will get wet, plastic included. No honest supplier can promise a dry underside in every building.
What changes is the damage. An ASA/PVC sheet has no metal and cannot rust when it is wet. The frame under it is another matter: steel purlins can rust and timber can rot if drips land on them for years, which is a good reason to deal with the cause.

Green corrugated roof with skylight sheets, Vietnam
How do you stop condensation under a roof?
- Let the moist air out: openings at the eaves and at the ridge let air move through the roof space.
- Cut the moisture at its source: extract fans for kitchens and laundries, ventilation designed for animal houses, lids on tanks and vats.
- Do not close in a roof space with insulation or a ceiling unless your builder has designed how moisture is controlled.
- Fix the sheets correctly so rain cannot get in and be mistaken for condensation.
- Keep slopes between 20 and 45% so water on the top surface drains fast.
- Follow local building codes for insulated and ventilated roofs, and have the design checked by your builder.
Can foam or insulation go under an ASA/PVC roof sheet?
Buyers ask this often enough that Whether a foam layer or other insulation suits your building, and how it is fixed, depends on the building and the local rules. Ask Santiago with your building type, roof size and climate before you plan it, and let your builder design the insulation and ventilation together.

Cream-coloured sheet fixed on purlins, Vietnam
Why do bare metal roofs drip, heat up and roar in rain?
Mr Quyen holds a white tile sheet in the Santiago factory in Vietnam and explains in English, with captions, why bare metal roofs are hot, noisy in rain and costly to repair. The short then moves to a red tile roof on a house and a finished grey tile roof beside the gutter.
Heat and rain noise: Santiago ASA/uPVC roofing explained (Santiago video on YouTube).
More short videos on heat and drips
Both clips below come from Santiago's own YouTube channel and were filmed at the factory in Vietnam or on Santiago roofs.
How are tile sheets screwed down on site?
In under a minute the short goes from the Santiago factory floor to a grey tile-profile roof on site: some sheets already fixed, installers screwing down the rest, and a finished run next to the gutter.
Santiago uPVC tile roofs on site (Santiago video on YouTube).
How does the sheet react to heat?
The heat-test short: grey and red sheets under a flame, Mr Quyen on grey sheets at the factory, then a warehouse roof re-laid in blue. It shows how the sheet behaves under heat, not a certified fire rating.
Heat test and a warehouse re-roof with uPVC sheets (Santiago video on YouTube).
Santiago – a leading exporter of ASA/PVC roofing from Vietnam
Santiago roofing is produced and loaded into containers at our factory in Vietnam. It has been exported to India since 2023, Thailand since 2024 and the USA since 2025. Every export shipment comes with a commercial invoice, packing list, bill of lading and a certificate of origin (C/O) issued by Vietnam's Ministry of Industry and Trade, which importers use to claim the duty preference of their trade agreement.
| Item | Details |
|---|---|
| HS code | 3925.90.00 (ASA/PVC roofing sheets) |
| Certificate of origin | Form D (ASEAN), Form AI (India), Form AK / VK (Korea), Form AJ / VJ (Japan), Form VC (Chile), CPTPP proof of origin |
| Shipped from | Vietnam, by container |

Certificate of origin Form AI (ASEAN–India) for Santiago ASA/PVC roofing sheets, HS 39259000, certified on 24 September 2026. Buyer details are hidden.

The Santiago team beside a loaded export container at the factory, November 2024

Loading Santiago roof tiles into an export container
Frequently asked questions
How do I stop condensation dripping from my corrugated roof?
Ventilate the roof space at the eaves and ridge, reduce moisture at its source, and have insulation or a ceiling designed with moisture control by your builder. A sheet that conducts less heat, such as ASA/PVC, also helps.
Do PVC roofing sheets get condensation?
Less readily than bare metal, because plastic conducts heat less and its underside cools less on clear nights. In very humid buildings any surface can still get wet, so ventilation still matters.
Are anti condensation roofing sheets worth it?
The usual anti-condensation sheet is a metal sheet with an absorbent fleece on the underside that holds droplets until they dry. It reduces dripping but does not remove the cause; ventilation and moisture control do.
Can I add foam insulation under an ASA/PVC roof sheet?
Ask Santiago with your building type, roof size and climate, and have your builder design the insulation and ventilation together under local codes.
Does condensation damage an ASA/PVC roof?
The sheet has no metal and cannot rust. Long-term drips can still rust steel purlins or rot timber under it, so find and fix the cause.
Read more
- The underside of a PVC roof sheet: can it be your ceiling?
- What Santiago's heat, noise and corrosion tests show
- A rust-free roof: ASA/PVC sheets on FRP purlins
- ASA screw caps and fixing on the top of the wave
- ASA/PVC roofing sheet, 6 square waves
Read next on this topic
Main guide: Heat Resistant Roofing Sheet for a Hot Climate
Sources for the figures in this article
- Profiles, 2.5–3.0 mm thickness and 10-year warranty: Santiago ASA/PVC product specification.
- HS code 3925.90.00: Harmonized System Chapter 39 (builders' ware of plastics), as applied in Vietnam's export tariff.
- Certificates of origin (Form D, AI, AK/VK, AJ/VJ, VC, CPTPP): issued by Vietnam's Ministry of Industry and Trade under the country's free trade agreements.
- Minimum order of one 40 ft container (about 5,000 m) and about 5 days for production and loading: Santiago export desk, October 2026.
Updated 03/11/2026. Santiago Import Export Co., Ltd, Vietnam. WhatsApp +84 935 391 495 (Mr. Quyen), hotline +84 965 437 316 (Mrs. Ly), email salessantiagoroofing@gmail.com.