Mr Quyen - Santiago. Posted 14/11/2026
Santiago does not hold a fire rating, class or certificate for its ASA/PVC roofing sheets, so it does not sell them as fire resistant roofing sheets. As a general material fact, PVC contains chlorine and tends to stop burning once the flame is taken away, but that is a property of the plastic, not a fire rating for a roof. If your building needs a rating, ask any supplier for a test report to your local standard and follow your local fire code.

Cream sheets on a factory production line, Vietnam
What does "fire resistant roofing sheet" actually mean?
In a building code the phrase only means something when it points to a test. A laboratory tests a sample to a named standard and issues a report with a result, often a class or a rating. Standards differ from country to country, and so do the tests: some measure how a material reacts to a small flame, others how a complete roof covering on its deck copes with fire from outside. A result applies to the product and the build-up that were tested, not to a material in general.
A product listing that says "fire resistant" with no standard, no laboratory and no report behind it gives you nothing to show a building inspector.
Are PVC roofing sheets fire resistant?
Santiago makes no fire claim for its sheets, in either direction. What can be said is general chemistry: PVC contains chlorine, and PVC tends to stop burning when the flame that lit it is taken away. That is why it is sometimes described as self-extinguishing.
It does not make a PVC roof fireproof. Like other thermoplastics, PVC softens and loses its shape when it gets hot enough, and smoke from burning plastic is harmful to breathe. How a roof behaves in a real fire also depends on the frame, the space under it, what is stored inside and how close the neighbouring buildings are. That is why codes test whole assemblies rather than taking a material's word for it.
Is PVC roofing flammable? What the flame video shows
PVC will burn while a flame is held to it. The video below shows grey and red sheets under a flame, then a warehouse roof re-laid in blue. It shows how the sheet behaves under a flame in front of a camera. It is a demonstration, not a laboratory test, and it is not a fire rating.

Inside a warehouse, with an overhead crane under the roof, Vietnam
What should you ask any supplier for?
| Ask for | Why it matters |
|---|---|
| The name and number of the test standard | It has to be a standard your building code accepts |
| The name of the laboratory | Some authorities accept reports only from certain laboratories |
| The full report, not a single line from it | The report says exactly what was tested and what the result was |
| Product details in the report | Thickness, layers and profile should match what you are buying |
| Whether the material or the roof covering was tested | Roof rules often ask about the covering on its deck, not the sheet alone |
| Date and product name | They should match the current product and the invoice |
These questions apply to every roofing material and every supplier, plastic or not. If a supplier cannot answer them, treat the fire claim as unproven.
Can I have Santiago's sheets tested locally?
Yes. Santiago sends free samples (the buyer pays the courier) in 2.5 or 3.0 mm and in the colour you plan to use, and a laboratory in your country can test them to the standard your project needs. Tell the laboratory exactly which thickness and profile you will order, because a result for one does not automatically cover another.
Where do fire rules matter most on a roof?
Your local fire code decides this, not the roofing supplier. In many places the rules are strictest for factories and warehouses that store goods that burn, buildings close to a boundary or to neighbours, roofs over escape routes and buildings where many people gather. Ask your architect, engineer or local fire authority what your roof has to meet before you choose any material.

Aerial view of blue tile sheets on a roof frame, Vietnam
Which site precautions apply to any plastic roof?
- Finish welding, cutting and grinding on the steel frame before the sheets go up, so sparks cannot land on them.
- Keep the roof clear of chimneys, flues, kitchen exhausts and barbecue hoods, and use the detail your code or the appliance maker requires where a flue passes through a roof.
- Store the sheets away from fires, hot work and burning rubbish on site.
- Do not burn offcuts; dispose of them with other plastic waste.
- In a factory, keep hot processes and heaters away from the underside of the roof.
Which documents does Santiago provide?
| Document | Available | What it covers |
|---|---|---|
| Fire rating, class or certificate | No | Santiago holds none for its sheets |
| ISO 9001:2015 certificate ICI-23087.D | Yes | The factory's quality management system |
| Quatest test results | Yes | The properties listed in the report; not a fire rating |
| Quality certificate (CQ) | With every lot | Product, thickness and lot |
| Free samples | Yes, buyer pays the courier | Your own checks or a test by a local laboratory |
Santiago supplies sheets and accessories and sends installation videos; it does not install, and it gives no structural, wind or fire rating. The design of the building, and its approval under local rules, stays with your builder, engineer and local authority.

Ridge caps in several colours at a factory, Vietnam
What happens when a flame is held to the sheet?
The heat-test short: grey and red sheets under a flame, Mr Quyen on grey sheets at the factory, then a warehouse roof re-laid in blue. It shows how the sheet behaves under heat in a demonstration; it is not a certified fire rating.
Heat test and a warehouse re-roof with uPVC sheets (Santiago video on YouTube).
More short videos with heat demonstrations
Two more English shorts from the Santiago YouTube channel. A flame demonstration is not a fire rating.
What does a flame demonstration on the stack show?
Red tile sheets go up onto a house, a flame is put to a stack of sheets, and the short ends on a blue warehouse roof being fitted. A flame test is a demonstration, not a fire rating.
Santiago PVC roofing tiles in real conditions (Santiago video on YouTube).
Torch, truck and packing at the factory
The short opens with a red ridge piece under a truck tyre, then Mr Quyen holds a gas torch to blue and red tile sheets on the factory yard and ends on strapped stacks of sheets ready to ship. A flame test is a demonstration, not a fire rating.
Truck, flame and packing: Santiago ASA/PVC sheets at the factory (Santiago video on YouTube).
Santiago – a leading exporter of ASA/PVC roofing from Vietnam
Santiago roofing is produced and loaded into containers at our factory in Vietnam. It has been exported to India since 2023, Thailand since 2024 and the USA since 2025. Every export shipment comes with a commercial invoice, packing list, bill of lading and a certificate of origin (C/O) issued by Vietnam's Ministry of Industry and Trade, which importers use to claim the duty preference of their trade agreement.
| Item | Details |
|---|---|
| HS code | 3925.90.00 (ASA/PVC roofing sheets) |
| Certificate of origin | Form D (ASEAN), Form AI (India), Form AK / VK (Korea), Form AJ / VJ (Japan), Form VC (Chile), CPTPP proof of origin |
| Shipped from | Vietnam, by container |

Certificate of origin Form AI (ASEAN–India) for Santiago ASA/PVC roofing sheets, HS 39259000, certified on 24 September 2026. Buyer details are hidden.

The Santiago team beside a loaded export container at the factory, November 2024

Loading Santiago roof tiles into an export container
Frequently asked questions
Are PVC roofing sheets fire resistant?
Santiago holds no fire rating, class or certificate for its ASA/PVC sheets and makes no fire claim. Any "fire resistant" claim should come with a test report to a named standard.
Is PVC roofing flammable?
PVC burns while a flame is held to it. As a general material fact it contains chlorine and tends to stop burning when the flame is taken away, but that is not a fire rating for a roof.
Is the flame test in Santiago's video a fire rating?
No. It is a demonstration filmed at the factory, not a laboratory test to any standard.
How can I get a fire test for my project?
Ask Santiago for free samples (the buyer pays the courier) in the thickness and colour you will order, and have a local laboratory test them to the standard your code requires.
Which rules decide whether a plastic roof is allowed?
Your local building and fire codes. Check them with your architect, engineer or fire authority before you choose a roofing material.
Read more
- How ASA/PVC roofing sheets are made
- Why the ASA surface layer matters on a PVC roof
- How to check a PVC roofing sheet supplier
- What Santiago's heat, noise and corrosion tests show
- ASA/PVC roof tile sheet
Read next on this topic
Main guide: UPVC Roofing Sheets Advantages and Disadvantages
Sources for the figures in this article
- Profiles, 2.5–3.0 mm thickness and 10-year warranty: Santiago ASA/PVC product specification.
- HS code 3925.90.00: Harmonized System Chapter 39 (builders' ware of plastics), as applied in Vietnam's export tariff.
- Certificates of origin (Form D, AI, AK/VK, AJ/VJ, VC, CPTPP): issued by Vietnam's Ministry of Industry and Trade under the country's free trade agreements.
- Minimum order of one 40 ft container (about 5,000 m) and about 5 days for production and loading: Santiago export desk, October 2026.
Updated 03/11/2026. Santiago Import Export Co., Ltd, Vietnam. WhatsApp +84 935 391 495 (Mr. Quyen), hotline +84 965 437 316 (Mrs. Ly), email salessantiagoroofing@gmail.com.